Product Overview
Specification Table
Compare models
| GEN-16P-US-480-V2 Generator 16kW 480V | GEN-16P-US-240-V2 Generator 16kW 240V THIS | |
|---|---|---|
| Engine / Motor | Honda GX-690 | Honda GX-690 |
| Output | 16 kW | 16.8 kW max / 15 kW continuous |
| Power / Voltage | 480V 3 Phase | 120V single phase, 240V three phase |
| Weight | 342 lbs | 342 lbs |
| Price | $10,900.00 | $10,900.00 |
| Check › | Viewing |
Specs from Makinex manuals. Prices update live and reflect current promotions.
FAQ about this model
How much power does this generator put out?
Per the Makinex 16kW brochure, three-phase output is 16.8 kW maximum and 15 kW continuous, with 40 A maximum / 36 A continuous on three-phase and 23 A maximum / 20 A continuous on single-phase. Size equipment that runs for long periods against the 15 kW continuous figure.
What voltage and outlet types does it have?
It supplies 120V single phase and 240V three phase at 60 Hz. The panel has 1× 20A GFCI single-phase socket, 1× 50A L14-30R three/single-phase socket, 1× 50A CS6389 three/single-phase socket and 1× 50A CS8369 three-phase socket. Check these connectors against the plugs on your equipment before you commit.
Which engine does it use, and what fuel does it need?
It is powered by a Honda GX690 (688 cc twin-cylinder, air-cooled petrol engine) with electric key start. The fuel tank holds 9.0 gallons and fuel economy is 0.92 gallons per hour at 50% load. Routine servicing follows Honda's schedule for that engine — oil and filter changes, air cleaner, spark plugs.
How heavy is it, and how big is it?
Dry weight is 342 lbs and dimensions are 30.4 in (L) × 20.8 in (W) × 35.5 in (H). That is well beyond a one-person lift, so plan on a forklift, hoist, or two people with proper handling equipment for loading and positioning.
How loud is it when running?
The brochure lists 72 dB at no load, measured at 7 m; Makinex does not publish a full-load noise figure. It is still clearly audible close up, so site it away from operators and occupied areas where the layout allows. OSHA sets the workplace noise exposure rules that apply on US job sites, and hearing protection is judged on total daily exposure, not this unit alone.
Who is this generator suited to, and who should look at something else?
It suits contractors and sites needing up to 15 kW continuous three-phase power at 240 V that want three-phase and single-phase outlets from a single unit. It is a poor fit if you need a different supply voltage, more capacity, or something light enough to move by hand at 342 lbs. Check your largest single load, including its starting demand, against the listed outputs.
Shipping & Returns
We offer standard 1-5 business day shipping (following dispatch) via LTL Freight, FedEx, UPS, DHL, or USPS. Orders typically process in 1-2 business days (starting the following business day). Shipping rates are usually calculated at checkout; however, we reserve the right to provide custom shipping quotes for oversized or specialized equipment.
More information on shipping and returns can be found here.