What can this jib crane lift?
Every FL-Series model on this page is rated at 1/4 ton capacity, regardless of span or HUB height. That rating applies to the crane structure; what you can actually lift also depends on the hoist and rigging you attach, which are not covered by these specifications. If your loads exceed 1/4 ton, choose a higher-rated crane instead.
What spans and heights are available?
Spans run from 6 ft to 14 ft, and HUB heights are offered at 8 ft, 10 ft and 12 ft — fifteen model combinations in total. For example, the FL586 is an 8 ft HUB with a 6 ft span, while the FL51214 is a 12 ft HUB with a 14 ft span. Measure your overhead clearance and required reach before selecting a model.
How much does the crane weigh?
Weights range from 490 lbs for the FL586 up to 1,036 lbs for the FL51214. Weight increases with both span and HUB height: the FL5810 is 554 lbs, the FL51010 is 592 lbs and the FL51210 is 630 lbs. Confirm the weight of the exact model you order so you can plan handling, placement and floor loading.
What does "foundationless" mean for installation?
It means the crane mounts to an existing floor instead of requiring a separate poured foundation for the mast. The base anchors to the slab and the mast carries the load, so no pit or dedicated footing is part of the design. These specifications do not state slab thickness or anchor requirements, so have those verified for your site before installing.
Does this crane require electrical power?
The crane structure itself does not require power — it is a mast and boom that supports a hoist. Any power requirement comes from the hoist you mount on it. No hoist, trolley or electrical supply is listed in these specifications, so budget and plan for those separately once you have chosen a hoist.
Who is this crane not a good fit for?
It is not suitable if you lift more than 1/4 ton, need reach beyond a 14 ft span, or need clearance under a HUB height lower than 8 ft. It is also a fixed floor-mounted pillar crane, so it serves one area — a single workstation, machine cell or loading point — rather than moving loads across a facility.